Showing
of 861
Compare
Mfr Part #
Quantity Available
Price
Series
Package
Product Status
Type
Input Range
Output
Isolation
Response Time
Accuracy
Voltage - Supply
Mounting Type
Termination Style
Operating Temperature
Approval Agency
IsoBlock I-FG-1C
ISOBLOCK I-FG-1C (25A 10V)
TRANSDUCER CURRENT 9-28VDC
Verivolt LLC
26
In Stock
1 : 186,88000 €
Box
Box
ActiveCurrent Transducer0 ~ 25A±10V1200V (Working)5µs±0.2%9 ~ 28VDCDIN RailSpring Terminal-25°C ~ 70°C-
IsoBlock V-1C
ISOBLOCK V-1C (1000V 10V)
TRANSDUCER VOLTAGE 9-28VDC
Verivolt LLC
177
In Stock
1 : 294,48000 €
Box
Box
ActiveVoltage Transducer±1000V±10V1500V (Working)2.8µs±0.2%9 ~ 28VDCDIN RailSpring Terminal-25°C ~ 70°C-
IsoBlock V-1C
ISOBLOCK V-1C (1500V 10V)
TRANSDUCER VOLTAGE 9-28VDC
Verivolt LLC
72
In Stock
1 : 294,48000 €
Box
Box
ActiveVoltage Transducer±1500V±10V1500V (Working)2.8µs±0.2%9 ~ 28VDCDIN RailSpring Terminal-25°C ~ 70°C-
IsoBlock I-FG-1C
ISOBLOCK I-FG-1C (50A 10V)
TRANSDUCER CURRENT 9-28VDC
Verivolt LLC
20
In Stock
1 : 186,88000 €
Box
Box
ActiveCurrent Transducer0 ~ 50A±10V1200V (Working)5µs±0.2%9 ~ 28VDCDIN RailScrew Terminal, Spring Terminal-25°C ~ 70°C-
CR4510-250,CR4510-500
CR4510-250
TRANSDUCER VOLTAGE 24VDC
CR Magnetics Inc.
11
In Stock
1 : 191,17000 €
Box
Box
ActiveTrue RMS AC Voltage Transducer0 ~ 250VAC0 ~ 5VDC2500VDC250ms0.5%24VDCDIN RailScrew Terminal0°C ~ 60°CCE, cURus
2810612
2810612
TRANSDUCER CURRENT 24VDC
Phoenix Contact
7
In Stock
1 : 282,49000 €
Bulk
Bulk
ActiveCurrent Transducer0 ~ 5A0 ~ 20mA4000VAC (Test)--24VDCDIN RailScrew Terminal-20°C ~ 60°CATEX, cULus
IsoBlock V-1C
ISOBLOCK V-1C (500V 10V)
TRANSDUCER VOLTAGE 8-28VDC
Verivolt LLC
16
In Stock
1 : 294,48000 €
Box
Box
ActiveVoltage Transducer±500V±10V1500V (Working)2.8µs±0.2%8 ~ 28VDCDIN RailSpring Terminal-25°C ~ 70°C-
IsoBlock V-1C
ISOBLOCK V-1C (300V 10V)
TRANSDUCER VOLTAGE 9-28VDC
Verivolt LLC
6
In Stock
1 : 294,48000 €
Box
Box
ActiveVoltage Transducer±300V±10V1500V (Working)2.8µs±0.2%9 ~ 28VDCDIN RailSpring Terminal-25°C ~ 70°C-
IsoBlock V-1C
ISOBLOCK V-1C (50V 10V)
TRANSDUCER VOLTAGE 9-28VDC
Verivolt LLC
12
In Stock
1 : 294,48000 €
Box
Box
ActiveVoltage Transducer±50V±10V1500V (Working)2.8µs±0.2%9 ~ 28VDCDIN RailSpring Terminal-25°C ~ 70°C-
2308027
2308027
TRANSDUCER CURRENT 24VDC
Phoenix Contact
4
In Stock
1 : 251,09000 €
Bulk
Bulk
ActiveCurrent Transducer0 ~ 100A4 ~ 20mA300VAC (Working), 3500VAC (Test)150ms-24VDCChassis Mount, DIN RailSpring Terminal-40°C ~ 65°CCE, cULus
IsoBlock V-1C
ISOBLOCK V-1C (1000V 5V)
TRANSDUCER VOLTAGE 9-28VDC
Verivolt LLC
20
In Stock
1 : 311,46000 €
Box
Box
ActiveVoltage Transducer±1000V±5V1500V (Working)2.8µs±0.2%9 ~ 28VDCDIN RailSpring Terminal-25°C ~ 70°C-
ISOBLOCK-I-ST-1C-(10A-10V)_View1
ISOBLOCK I-ST-1C (10A 10V)
TRANSDUCER CURRENT 9-28VDC
Verivolt LLC
1
In Stock
1 : 328,46000 €
Box
Box
ActiveCurrent Transducer0 ~ 10A±10V2000V (Working)2.8µs±0.2%9 ~ 28VDCDIN RailScrew Terminal, Spring Terminal-25°C ~ 70°C-
2906242
2906242
TRANSDUCER VOLTAGE 24VDC
Phoenix Contact
16
In Stock
1 : 343,01000 €
Bulk
Bulk
ActiveVoltage Transducer±660VDC±10V5300VAC (Test)16ms-24VDCDIN RailScrew Terminal-25°C ~ 60°CCE, cULus
2814715
2814715
TRANSDUCER CURRENT 20-30VDC
Phoenix Contact
6
In Stock
1 : 405,57000 €
Bulk
Bulk
ActiveCurrent Transducer0 ~ 11A±10VDC, 0 ~ 20mA300VAC (Working), 4000VAC (Test)40ms, 330ms-20 ~ 30VDCDIN RailScrew Terminal-20°C ~ 60°CCE, cULus
2814731
2814731
TRANSDUCER CURRENT 20-30VDC
Phoenix Contact
4
In Stock
1 : 449,71000 €
Bulk
Bulk
ActiveCurrent Transducer0 ~ 11A±10VDC, 0 ~ 20mA300VAC (Working), 4000VAC (Test)40ms, 330ms-20 ~ 30VDCDIN RailScrew Terminal-20°C ~ 60°CCE, cULus
IsoBlock I-FG-4C
ISOBLOCK I-FG-4C (25A 10V)
TRANSDUCER CURRENT 9-28VDC
Verivolt LLC
7
In Stock
1 : 656,91000 €
Box
Box
ActiveCurrent Transducer0 ~ 25A±10V1200V (Working)5µs±0.2%9 ~ 28VDCDIN RailSpring Terminal-25°C ~ 70°C-
IsoBlock V-4C
ISOBLOCK V-4C (100V 10V)
TRANSDUCER VOLTAGE 9-28VDC
Verivolt LLC
18
In Stock
1 : 985,37000 €
Box
Box
ActiveVoltage Transducer±100V±10V1500V (Working)2.8µs±0.2%9 ~ 28VDCDIN RailSpring Terminal-25°C ~ 70°C-
IsoBlock V-4C
ISOBLOCK V-4C (500V 10V)
TRANSDUCER VOLTAGE 9-28VDC
Verivolt LLC
7
In Stock
1 : 985,37000 €
Box
Box
ActiveVoltage Transducer±500V±10V1500V (Working)2.8µs±0.2%9 ~ 28VDCDIN RailSpring Terminal-25°C ~ 70°C-
IsoBlock V-4C
ISOBLOCK V-4C (1000V 10V)
TRANSDUCER VOLTAGE 9-28VDC
Verivolt LLC
6
In Stock
1 : 985,37000 €
Box
Box
ActiveVoltage Transducer±1000V±10V1500V (Working)2.8µs±0.2%9 ~ 28VDCDIN RailSpring Terminal-25°C ~ 70°C-
IsoBlock V-4C
ISOBLOCK V-4C (300V 10V)
TRANSDUCER VOLTAGE 9-28VDC
Verivolt LLC
6
In Stock
1 : 985,37000 €
Box
Box
ActiveVoltage Transducer±300V±10V1500V (Working)2.8µs±0.2%9 ~ 28VDCDIN RailSpring Terminal-25°C ~ 70°C-
IsoBlock V-4C
ISOBLOCK V-4C (1500V 10V)
TRANSDUCER VOLTAGE 9-28VDC
Verivolt LLC
4
In Stock
1 : 985,37000 €
Box
Box
ActiveVoltage Transducer±1500V±10V1500V (Working)2.8µs±0.2%9 ~ 28VDCDIN RailSpring Terminal-25°C ~ 70°C-
CR4620,CR4510,CR4810,CR4820 Parts
CR4620-150
TRANSDUCER VOLTAGE 24VDC
CR Magnetics Inc.
1
In Stock
1 : 111,10000 €
Box
Box
ActiveAverage RMS AC Voltage Transducer0 ~ 150VAC4 ~ 20mA2500VDC250ms0.5%24VDCDIN RailScrew Terminal0°C ~ 60°CCE, cURus
IsoBlock I-FG-1C
ISOBLOCK I-FG-1C (15A 10V)
TRANSDUCER CURRENT 9-28VDC
Verivolt LLC
15
In Stock
1 : 186,88000 €
Box
Box
ActiveCurrent Transducer0 ~ 15A±10V1200V (Working)5µs±0.2%9 ~ 28VDCDIN RailSpring Terminal-25°C ~ 70°C-
IsoBlock I-FG-1C
ISOBLOCK I-FG-1C (6A 10V)
TRANSDUCER CURRENT 9-28VDC
Verivolt LLC
14
In Stock
1 : 186,88000 €
Box
Box
ActiveCurrent Transducer0 ~ 6A±10V1200V (Working)5µs±0.2%9 ~ 28VDCDIN RailSpring Terminal-25°C ~ 70°C-
CR4510-50
CR4510-50
TRANSDUCER VOLTAGE 24VDC
CR Magnetics Inc.
7
In Stock
1 : 191,17000 €
Bulk
Bulk
ActiveTrue RMS AC Voltage Transducer0 ~ 50VAC0 ~ 5VDC2500VDC250ms0.5%24VDCDIN RailScrew Terminal0°C ~ 60°CCE, cURus
Showing
of 861

Current/Voltage Transducer Monitors


Industrial current or voltage transducers are used to monitor variable or non-sinusoidal sources, trigger peripheral devices in phase-fired control systems, monitor ground current, and other voltage or current monitoring applications. Output types include analog voltage or current, and positive and negative fixed voltages with accuracy from 0.2 to 2%.